Anand Electric Agency

Chennai, Tamil Nadu

GST No. 33AJMPA9398J1ZP

Send Email
0804763084786% Response Rate
Search

Home » Our Product Range » Circuit Breakers


Circuit Breakers

Wholesale Trader of a wide range of products which include molded case circuit breakers, residual current circuit breaker, weg electric mccb, motor protection circuit breaker, abb circuit breaker and abb mcb.

Molded Case Circuit Breakers

REQUEST CALLBACK

Molded Case Circuit Breakers
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2,500 / PieceGet Latest Price

Product Brochure
Product Details:
No. of PolesTriple Pole
Breaking Capacity22 kA @480 VAC
BrandEaton
Voltage480VAC, 250 VDC
Rated Current15 A
Frequency50/60 Hz
Type of TripN.I.T.U
Circuit Breaker TypeG Frame
Federal Specification13b

Features include:
  • UL 489 listed performance for branch circuit overcurrent protection and disconnecting means
  • Patented contact conductor designs featuring high-speed "blow-open" action, providing superior performance when high level fault currents produce extraordinary electromechanical forces
  • Advanced arc extinguishing technology (arc fault protection)
  • Toggle handle provides three positions (on/ off/ tripped) along with visual indicators
  • Manufactured in ISO 9000 certified facilities
  • HACR (heating, air conditioning and refrigeration) rated
  • G-Frame (15 to 100 Amp) and F-Frame (100 to 225 Amp) size units are suitable for reverse feed
  • K-Frame and L-Frame breakers include 3-pole adjustable magnetic trip
  • G-Frame (70 to 90A) and F-Frame (60 to 90A) breakers plus additional shaft lengths and NEMA 4/4X ratings for handles
  • Type C361 door interlocking safety handle kits are now available
Listings:
  • UL 489 MCCB, File: E7819
  • Field-installed accessories: UL file E64983
  • CSA 22.2 No.5, File: 43556
  • IEC 157-1
  • NEMA Standards Publication No. AB1-1993
Yes! I am interested

Residual Current Circuit Breaker

REQUEST CALLBACK

Residual Current Circuit Breaker
  • Residual Current Circuit Breaker
  • Residual Current Circuit Breaker
  • Residual Current Circuit Breaker
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 250 / PieceGet Latest Price

Product Details:
BrandABB
No. of PolesDouble Pole
Voltage230/400 V (Rated Voltage)
Rated current25 A
Model Name/NumberF202
Type of Residual CurrentA Type
Rated Residual Current30 mA
Frequency Range50-60 Hz
Ambient Air Temperature-25 to 55 DegreeC
Maximum Operating Voltage277 V AC
Dimension0.035 x 0.085 x 0.069 m
Weight0.200 kg

    Yes! I am interested

    WEG Electric MCCB

    REQUEST CALLBACK

    WEG Electric MCCB
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 5,000 / PieceGet Latest Price

    Product Details:
    No. of PolesTriple Pole
    Breaking Capacity35 kA
    BrandWEG
    Voltage480VAC
    Rated Current500 Amp
    Model Number/NameUBW 600
    Breaker Frame Size600 mm
    Trip CurveMolded Case

    Details:
    • Accessories for the UBW series include 2 types of handles, rotary and flange style.
    • This series replaced the discontinued Weg ACW series of molded case circuit breakers.
    Yes! I am interested

    Motor Protection Circuit Breaker

    REQUEST CALLBACK

    Motor Protection Circuit Breaker
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 2,000 / PieceGet Latest Price

    Product Details:
    Rated Current6.3 A
    Breaking Capacity10 kA
    Frequency50 Hz
    Voltage240V
    MaterialPlastic Body
    Model Name/NumberDZ518(GV2-M)
    BrandKelever

    DZ518 the series electric motor protection circuit breaker, uses the modular design, the contour is artistic, the volume is small, breaks protects, inside sets hot relay, the function is very strong, the versatility is really good. The DZ518 series conforms to IEC60947-2 and IEC 60947-4.1 as well as the EN60947-1 standard. The switch and the contact device may compose the electric motor is direct starts. The DZ518 Series outer covering protection rankmay achieve IP65. .
    Yes! I am interested

    ABB Circuit Breaker

    REQUEST CALLBACK

    ABB Circuit Breaker
    • ABB Circuit Breaker
    • ABB Circuit Breaker
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 380 / PieceGet Latest Price

    Product Brochure
    Product Details:
    No. Of Poles4 Poles
    Usage/ApplicationIndustrial / Home & etc.
    Model Name/NumberM204-32A
    Rated Current32 A
    Frequency Range50-60 Hz
    Rated Ultimate Short-Circuit Breaking Capacity(400 V AC) 15 kA
    Rated Service Short-Circuit Breaking Capacity(400 V AC) 7.5 kA
    Pollution Degree3
    Contact Position IndicationRed On / Green Off
    Mechanical Endurance20000 cycle
    Tightening Torque2.8 Nm
    Built-In Depth69 mm
    Ambient Air Temperature-25 to 55 Deg C
    Dimension70 mm x 69 mm x 88 mm
    Weight0.56 kg

    Connecting Capacity:
    • Busbar 10 / 10 mm²
    • Flexible with Ferrule 0.75 ... 16 mm²
    • Flexible 0.75 ... 16 mm²
    • Rigid 0.75 ... 25 mm²
    • Stranded 0.75 ... 25 mm²
    Yes! I am interested

    ABB MCB

    REQUEST CALLBACK

    ABB MCB
    • ABB MCB
    • ABB MCB
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 350 / Piece(s)Get Latest Price

    Product Brochure
    Product Details:
    No.of PolesFour Pole
    Rated Current32A
    BrandABB
    Breaking Capacity25 kA
    CertificationIEC/EN 60898-1, IEC/EN 60947-2
    Frequency50-60 Hz
    Tripping CharacteristicD
    Power Loss14.4 W at Rated Operating Conditions per Pole 3.6 W
    Operational Voltage440 V AC Max
    Rated Short-Circuit Capacity10 kA
    Dielectric Test Voltage50/60 Hz, 1 min: 2 kV
    Contact Position IndicationRed On / Green Off
    Electrical Endurance10000 AC Cycle
    Mechanical Endurance20000 cycle
    Tightening Torque2.8 Nm
    Built-In Depth69 mm
    Ambient Air Temperature-25 to 55 Deg C
    Busbar Connecting Capacity14-8 AWG
    Conductor Connecting Capacity14-4 AWG
    Dimensions70 mm x 69 mm x 88 mm
    Weight0.5 kg

    System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50% space.
    Yes! I am interested

    X


    Explore More Products

    Contact via E-mail
    Contact via SMS
    Anand Jain (CEO)
    Anand Electric Agency
    2nd Floor, No. 8,
    Chennai - 600001, Tamil Nadu, India
    Call Us: 
    Call Response Rate: 86%
    Share Us :



    Home  |   About Us   |  Our Product Range  |  Site Map  |   Contact Us

    © Anand Electric Agency. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited

    Anand Electric Agency